Abnormal signals of high-pressure boiler pipe

Mainly describe the abnormal signals of high-pressure boiler pipe in the eddy current testing, and list the respective causes and treatment for different kinds of abnormal signals in detail.

Abnormal signals causes and treatment of high-pressure boiler pipe in the eddy current testing. 

Abnormal signal:

1. The continuous alarm signal of the head and tail pipe.

Cause Analysis: ` external grating fouling a instrument signal gate fault b the head and tail pipe cut c improper adjustment of the pinch roller.

Approach: ` eliminate grating fouling,and check the grating work a the instrument signal gate fault must be repaired btreat as normal defects c readjust pinch roller clamp degree

2. regular alarm signal certain parts of the boiler pipe.

Cause Analysis: ` hot rolling process defects a finishing process defects b improper adjustment of the pinch roller c poor anti-interference ability of the coil.

Approach: ` normal defect treatment, timely feedback a identify the reasons for the elimination of defects b readjust the pinch roller clamp degrees c replace the coil.

3. There is a distinct continuous signal of the phase.

Cause Analysis: ` overheating , hemp or correction concave surface defects of the steel outer surface a the coil center changed b iron scrap embedded in the inner wall of coilcthe coil zero potential is too large.

Approach: ` readjust the instrument parameters, use 3kHz flaw detection, and make the information recording and feedback
a readjust the coil center
b carefully check coil inner wall, remove embedded iron scrap.
c replace the coil.

4. No significant bulk of the slug signal of the phase.

Cause Analysis: ` crumbs and other debris falling into the coils a there are bulk of the torn defect or wall contraction in the steel pipe b poor anti-interference ability of the coils.

Approach: ` remove the iron oxide scrap in the coilHealth Fitness Articles, and adjust the nozzle position and soot blowing time a treat as normal defect b replace the coil.

Source: Free Articles from ArticlesFactory.com

ABOUT THE AUTHOR


We are specialized in research ssaw steel pipe and erw steel pipe.



Health
Business
Finance
Travel
Technology
Home Repair
Computers
Marketing
Autos
Family
Entertainment
Law
Education
Communication
Other
Sports
ECommerce
Home Business
Self Help
Internet
Partners


Page loaded in 0.135 seconds